LIMITATION OF THE ACCURACY OF TEMPERATURE MEASUREMENT BY SEMICONDUCTOR SENSORS DEPENDING ON THE STABILIZATION COEFFICIENT OF THE OPERATING CURRENT

Authors

  • О.А. Абдулхаев Физико-технический институт АН РУз
  • Р.Р. Бебитов Физико-технический институт АН РУз
  • А.Р. Абдулхаева Физико-технический институт АН РУз
  • Д.М. Ёдгорова Физико-технический институт АН РУз

DOI:

https://doi.org/10.52304/.v20i5.121

Abstract

The dependence of accuracy of temperature measurement by semiconductor sensors on stabilization factor of the current source is investigated and the results are presented. It is shown that the presence of slope of the current-voltage characteristic, as well as its dependence on temperature, impose limitations on the measurement of accuracy depending on the stabilization factor of the current source, the value of the operating current and the region of the measured temperature.

Published

2018-09-21

How to Cite

Абдулхаев, О. ., Бебитов, Р. ., Абдулхаева, А. ., & Ёдгорова, Д. . (2018). LIMITATION OF THE ACCURACY OF TEMPERATURE MEASUREMENT BY SEMICONDUCTOR SENSORS DEPENDING ON THE STABILIZATION COEFFICIENT OF THE OPERATING CURRENT. “Uzbek Journal of Physics”, 20(5), 300–304. https://doi.org/10.52304/.v20i5.121