Experimental studies of signal amplification in the electrical circuit of an electronic thermometer
DOI:
https://doi.org/10.52304/.v25i4.473Keywords:
amplifier, circuit, sensor, temperature, thermostat, bipolar power supply, scale amplifierAbstract
A prototype of a low-level signal amplifier with the ability to provide stable signal amplification for use in electronic thermometer circuits has been proposed and experimentally implemented. The amplifier can operate in both unipolar and bipolar modes, which ensures convenience and simplicity in operation, as it eliminates the need for full bipolar power supply. The sensitivity of the amplifier ranges from 150 to 310 mV per 1°C, indicating its potential for use in electronic thermometer circuits.
Downloads
Published
2024-01-17
How to Cite
Хакимов, А. ., Рахматов, А. ., Герасименко, С. ., Закиров, Р. ., Aбдулхаев O., Кулиев, Ш., Истамов, Д. ., Абдулхаева, А., & Ёдгорова, Д. (2024). Experimental studies of signal amplification in the electrical circuit of an electronic thermometer. “Uzbek Journal of Physics”, 25(4). https://doi.org/10.52304/.v25i4.473
Issue
Section
03. Physical Electronics. Physical Kinetics and Plasma Physics