Setup and procedure for the analysis of uranium ore samples using the delayed neutron detection method

Authors

  • С.А. Бакиев Центр развития профессиональной квалификации медицинских работ ников при Министерстве здравоохранения
  • Т.С. Тиллаев Институт ядерной физики АН РУз
  • Ж. Рахманов Институт ядерной физики АН РУз

DOI:

https://doi.org/10.52304/.v28i2.655

Keywords:

uranium, ore samples, analysis method, delayed neutron registration method (MDN), Cf-252 andSb-Be neutron sources, detection limit, analysis performance

Abstract

The method of detecting delayed neutrons (MDN) during uranium fission is the most convenient and promising methods for analyzing uranium ores. The availability of high intensity Cf252 and Sb-Be neutron sources and the needs of the geological industry stimulated to create a
setup and analysis method using MDN, which allowed one to determine uranium with a detection limit of ≈10 g/t. The data obtained were used by one of the largest geological exploration
organizations in the Republic.

Published

2026-08-04

How to Cite

Бакиев, С., Тиллаев, Т., & Рахманов, Ж. (2026). Setup and procedure for the analysis of uranium ore samples using the delayed neutron detection method. “Uzbek Journal of Physics”, 28(2). https://doi.org/10.52304/.v28i2.655

Issue

Section

04. Atomic and Nuclear Physics, Particle Physics